200V 100A Battery Charge And Discharge Testing Machine EV Battery Pack Tester
Contact Person:Louis Yang Email: Louis@chinabatterymachine.com Tel:+86 13003860308 Whatsapp: +86 13003860308 Wechat:18659217588
Email: Louis@chinabatterymachine.com
Tel:+86 13003860308
Whatsapp: +86 13003860308
Wechat:18659217588
Item No.:
LITH-BTS-5V6APayment:
Credit Card, Paypal, T/T , Western Union, LCShipping port:
Xiamen PortLead Time:
5 days5V6A 8 Channel Lithium Ion Battery Testing Machine
Features
1. LITH-BTS-5V6A Battery tester equipment is an eight-channel battery analyzer to analyze polymer battery and cylindrical batteries from 12.0 mA to 6000 mA, up to 5V.
2. This battery test system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc. Our company manufactures various types of Li ion battery equipment. We welcome your contacts from any place of world.
Specifications
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Voltage Range |
Charge:25mV~5V;Discharge:1.0V~5V |
Accuracy |
± 0.05% of FS |
|
Stability |
0.05% of FS |
|
Current |
Per Channel Output Current Range |
Range1:0.5mA~0.1A;Range2:0.1A~6A;Range3: 3A-6A |
Accuracy |
± 0.05% of FS |
|
CV cut-off current |
Range 1: 0.2mA Range2: 6mA; Range3: 12mA; |
|
Stability |
0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
The Current gets to 6A Hardware Response Time is 1ms |
Step Time Range |
0.1s≤Single Step Time Range≤365*24 h,
Time Form Support 00:00:00(h、min、s) |
|
Data Recording |
Record Condition |
Time△t:100ms |
Voltage△U:10mV |
||
Current△I:Range 1: 0.2mA Range2: 12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge、Constant Voltage Charge、
CC-CV Charge 、CP-Charge |
End Condition |
Voltage、Current、Relative Time、Capacity、-△V |
|
Discharge |
Discharge Mode |
Constant Current Discharge CP-D CR-D |
End Condition |
Current、Current、Relative Time、Capacity、-△V |
|
Pulse Model |
Charge |
Constant Current、Constant Power |
Discharge |
Constant Current、Constant Power |
|
Min Pulse Width |
500ms |
|
Pulse Number |
Single Pulse Step Support 32 different Pulse |
|
Charge r To Discharge |
One Pulse Step Can Support Continuous Charge And Discharge Change |
|
Stop Condition |
Voltage、 Relative Time |
|
DCIR Testing |
Support Custom Access Point And Count The DCR |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
l Power-down Data Protection |
l Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time |
||
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |
|
Data Management |
MySQL Database |
|
Communication Means |
TCP/IP Protocol |
|
Data Output |
EXCEL、TXT |
|
Communication Interface |
Ethernet Port |
|
Main Channels |
8 |
|
Dimensions |
3U,W*D*H:480*730*130(mm)per unit |
|
the total rack is 760*660*1960mm . The gross weight is 180KG |
||
Additional Function |
Test: Temperature; voltage |
|
Temperature range: minus 25C-110C( Thermistor) |
||
Temperature accuracy:± 1C |
||
Temperature resolution:0.1C |
||
Voltage range:-5V-5V |
||
Voltage accuracy:± 0.1% of FS |
||
|
Can set the parameter: Upper and lower limit of voltage; Upper and lower limit of temperature ;single cell voltage difference |
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃ |
Storage Temperature Range |
-10℃~45℃ |
Working Environment Relative Humidity Range |
30% ~ 80% RH |
Storage Environment Relative Humidity Range |
30% ~ 90% RH |