Lab High Accuracy Constant Temperature Circulating Water Jacket Viscometer
Contact Person:Louis Yang Email: Louis@chinabatterymachine.com Tel:+86 13003860308 Whatsapp: +86 13003860308 Wechat:18659217588
Email: Louis@chinabatterymachine.com
Tel:+86 13003860308
Whatsapp: +86 13003860308
Wechat:18659217588
Item No.:
LITH-TPayment:
L/C D/A D/P T/T Western UnionShipping port:
Xiamen PortLead Time:
5 daysLab 5-inch Color Touch Screen Brockfield Viscometer
Perfect integration of touch-screen technology, fast, accurate, easy to measure viscosity. Stepless debugging, can measure super high viscosity of the sample. 5-inch color touch screen can be comprehensive, visual display of a variety of parameters and working conditions. It has many advantages, such as many measuring parameters, rich display content, convenient operation, intuitive reading, high measuring precision, stable rotational speed, strong anti-interference performance, showing the curve of shear rate and viscosity, and so on.
Main features:
1 adopt ARM technology, built-in Linux system. The operation interface is simple and clear, through the creation of test program and data analysis, the viscosity test is carried out quickly and conveniently.
2. the viscosity test value is accurate : each measuring range is automatically calibrated by a computer , the precision is high , and the error is small ;
3. display is rich: in addition to viscosity (dynamic viscosity and kinematic viscosity), there are also temperature, shear rate, shear stress, measurement value as a percentage of the full range value (graphic display, range overflow alarm, automatic scanning, Maximum measurement range, date, time and so on under current rotor speed combination. Show kinematic viscosity when density is known.
4. complete functions: timing measurement, self-built 30 groups of test programs, access to 30 groups of measurement data, real-time display of viscosity curves, printing data and curves;
5. front level: level adjustment is intuitionistic and convenient;
6. stepless speed regulation:
RV1T series: 0.3-100 rpm, a total of 998 rotational speeds
RV2T series: 0.1-200rpm, 2000 revolutions
7. showing the curve of shear rate versus viscosity : the range of shear rate can be set , and displayed on the computer in real time ;Curve of time - to - viscosity can also be displayed
8. Standard USB interface: insert U disk to copy data directly
9.optional Pt100 temperature probe: wide temperature range, ranging from -20 ℃ to 300 ℃, and measuring precision 0.1 ℃;
10. Optional accessories rich: R1 rotor, temperature sensor, viscometer special thermostat bath, thermostat cup, printer, standard viscosity sample (standard silicone oil), etc.;
The measurable range is very large, ranging from 100 to 320 million MPA.
the torque of the filament, the shape of the rotor, the size of the rotational speed, and the range of viscosity measurement are the same as the imported viscometer of the same type. the measured viscosity and other data are well comparable with the imported similar instruments.
Widely used in paint, paint, cosmetics, ink, pulp, food, oil, starch, solvent adhesive, latex, biochemical products and other high viscosity industries.
Detailed technical parameters:
model |
LVDV-1T |
LVDV-2T |
Control / display mode |
5-inch color touch screen |
|
speed(r/min) |
0.3–100 infinitely variable speed , a total of 998 speed options |
0.1–200 infinitely variable speed , a total of 2000 speed options |
measuring range |
Rotor 1- 4: 10-2M mPa.s
ULR: 0.6-1K
Rotor 18: 3 - 10K
Rotor 25: 480 - 1.60M
Rotor 31: 30 - 100K
Rotor 34: 20 - 200K |
Rotor 1-4: 10–6M mPa.s
ULR: 0.3-6K
Rotor 18: 1.5 - 300K
Rotor 25: 240 – 4.8M
Rotor 31: 15 - 300K
Rotor 34: 30 - 600K |
rotor |
L1 - L4 (Standard)
Enhanced ultra-low viscosity adapter ULR (optional)
Small sample adapters (rotors 18,25,31,34)(optional)) |
|
Sample dosage |
Rotor 1- 4: 300 - 400ml
ULR: 21ml
Rotor 18:7ml
Rotor 25: 9ml
Rotor 31: 10.5ml
Rotor 34:11ml |
|
K = 1000; M = 1000000 |
||
measurement erro |
±1% (Newtonian liquid) |
|
repetitive error |
±0.5% (Newtonian liquid) |
|
Show shear response / shear rate |
standard configuration |
|
Timing function |
standard configuration |
|
Real-time display Viscosity curve |
Temperature-time curve
Viscosity-time curve
(The rheological curves of shear rate and viscosity can be displayed by optional data processing software) |
|
kinematic viscosity |
Density of samples to be entered |
|
Temperature measurement function |
Standard temperature probe interface (optional temperature probe) |
|
Automatic Scanning Function |
Automatically scan and recommend the preferred combination of rotor and rotation speed |
|
Maximum measurement range |
Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range |
|
Self-built Measuring Procedures |
Up to 30 groups (including rotor, speed, temperature, time, etc.) |
|
Preservation of measurements |
Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) |
|
put a seal on |
Data, curve can be printed (standard print interface, need to buy printer) |
|
data output interface |
USB: can insert U disk and copy data directly
RS232: Connect Computer |
|
thermostatic components |
Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) |
|
working power supply |
Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) |
|
outline dimension |
300 × 300 × 450(mm) |
model |
RVDV-1T |
HADV-1T |
HBDV-1T |
Control / display mode |
5-inch color touch screen |
||
speed(r/min) |
0.3–100 infinitely variable speed , a total of 998 speed options |
||
measuring
range
|
Rotor R2-R7:100-13M
Rotor 21: 50-167K
Rotor 27: 250-834K
Rotor 2: 500-1.7M
Rotor 29: 1K-3.3M |
Rotor R2-R7:200–26M
Rotor 21: 100-333K
Rotor 27: 500-1.7K
Rotor 28; 1K-3.3M
Rotor 29: 2K-6.6M |
Rotor R2-R7:800-104M
URL: 51.2 - 2K
Rotor 21: 400-1.3M
Rotor 27: 2K-6.7M
Rotor 28: 4K-13.3M
Rotor 29: 8K-26.6M |
K = 1000; M = 1000000 |
|||
rotor |
R2- R7(6, standard)
R1(apolegamy)
Enhanced ultra-low viscosity adapter ULR (optional)
Small sample adapters (rotor 21,27,28,29)(optional)) |
||
Sample dosage |
Rotor R1-R7: 500ml
ULR: 21ml
Rotor 21: 7.8ml
Rotor 27: 11.3ml
Rotor 28: 12.6ml
Rotor 29: 11.5ml |
||
measurement erro |
±1% |
||
repetitive error |
±0.5% |
||
Show shear response / shear rate |
standard configuration |
||
Timing function |
standard configuration |
||
Real-time display Viscosity curve |
Time-viscosity curve
Temperature-viscosity curve (optional temperature probe)
(Optional data processing software shows shear rate and viscosity curves) |
||
kinematic viscosity |
Density of samples to be entered |
||
Temperature measurement function |
Standard temperature probe interface (optional temperature probe) |
||
Automatic Scanning Function |
Automatically scan and recommend the preferred combination of rotor and rotation speed |
||
Maximum measurement range |
Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range |
||
Self-built Measuring Procedures |
Up to 30 groups (including rotor, speed, temperature, time, etc.) |
||
Preservation of measurements |
Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) |
||
put a seal on |
Data, curve can be printed (standard print interface, need to buy printer) |
||
data output interface |
USB: can insert U disk and copy data directly
RS232: Connect Computer |
||
thermostatic components |
Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) |
||
working power supply |
Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) |
||
outline dimension |
300 × 300 × 450(mm) |
model |
RVDV-2T |
HADV-2T |
HBDV-2T |
Control / display mode |
5-inch color touch screen |
||
speed(r/min) |
0.1–200 infinitely variable speed , a total of 2000 speed options |
||
measuring
range
|
Rotor R2-R7:100-4000M
Rotor 21: 25-500K
Rotor 27: 125-2.5M
Rotor 8:250-5M
Rotor 29: 500-10M |
Rotor R2-R7:200–8000M
Rotor 21: 50-1M
Rotor 27:250-5M
Rotor 28: 500-10M
Rotor 29: 1K-20M |
Rotor R2-R7:800-32000M
URL: 25.6 - 2K
Rotor 21: 200-4M
Rotor 27: 1K-20M
Rotor 28: 2K-40M
Rotor 29: 4K-80M |
K = 1000; M = 1000000 |
|||
rotor |
R2- R7(6, standard)
R1(apolegamy)
Enhanced ultra-low viscosity adapter ULR (optional)
Small sample adapters (rotor 21,27,28,29)(optional)) |
||
Sample dosage |
Rotor R1-R7: 500ml
ULR: 21ml
Rotor 21: 7.8ml
Rotor 27: 11.3ml
Rotor 28: 12.6ml
Rotor 29: 11.5ml |
||
measurement erro |
±1% |
||
repetitive error |
±0.5% |
||
Show shear response / shear rate |
standard configuration |
||
Timing function |
standard configuration |
||
Real-time display Viscosity curve |
Time-viscosity curve
Temperature-viscosity curve (optional temperature probe)
(Optional data processing software shows shear rate and viscosity curves) |
||
kinematic viscosity |
Density of samples to be entered |
||
Temperature measurement function |
Standard temperature probe interface (optional temperature probe) |
||
Automatic Scanning Function |
Automatically scan and recommend the preferred combination of rotor and rotation speed |
||
Maximum measurement range |
Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range |
||
Self-built Measuring Procedures |
Up to 30 groups (including rotor, speed, temperature, time, etc.) |
||
Preservation of measurements |
Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) |
||
put a seal on |
Data, curve can be printed (standard print interface, need to buy printer) |
||
data output interface |
USB: can insert U disk and copy data directly
RS232: Connect Computer |
||
thermostatic components |
Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) |
||
working power supply |
Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) |
||
outline dimension |
300 × 300 × 450(mm) |
Option:
1R1 Rotor
Sample viscosity below the lower limit of the range of each model, need to be equipped with R1 rotor
2. Enhanced ultra-low viscosity adapter (ULR)
Designed for low viscosity fluid measurement, there are two specifications for jacket type and non-jacket type, with a minimum detection limit of 1cP, depending on the type of viscometer used
3. Small sample adapters (rotors 21,27,28,29)
3. Temperature Probe (Temperature Sensor)
Temperature Probe (Temperature Sensor)
Temperature measurement range:-20-300°C
Measurement accuracy:0.1°C
4. Micro thermal printer
Direct connection with a viscometer
print data
Print curve
5. Special constant temperature bath for viscometer
5.1 CH1006N:
Temperature control range:
Room temperature plus 10 ℃ -100 ℃
Temperature control accuracy: 0.1 ℃
5.2 DC0506W:
Temperature control range : -5 to 100 ℃
Temperature control accuracy : 0.1 ℃
6. data-processing software
The rheological curves of shear rate and viscosity can be displayed by setting the measuring parameters of viscometer by computer.
X axis is shear rate, Y axis is viscosity