Lab Vacuum Single-sided Six Ports Glove Box with T Type Large Transition Bin
Contact Person:Louis Yang Email: Louis@chinabatterymachine.com Tel:+86 13003860308 Whatsapp: +86 13003860308 Wechat:18659217588
Email: Louis@chinabatterymachine.com
Tel:+86 13003860308
Whatsapp: +86 13003860308
Wechat:18659217588
Item No.:
LITH-PGBPayment:
L/C D/A D/P T/T Western UnionShipping port:
Xiamen PortLead Time:
5 daysLab Stainless Steel Vacuum Single-sided Four Ports Glove Box
Accessories list:
No. |
Accessory Name |
Quantity |
Unit |
Accessory pictures |
1 |
KF40 Clamp |
4 |
sets |
|
2 |
KF25 Clamp |
3 |
sets |
|
3 |
KF40 Bellow |
2 |
pcs |
|
4 |
KF25 Bellow |
1 |
pc |
|
5 |
Gloves |
4 |
pcs |
|
6 |
Glove seals |
8 |
pc |
|
7 |
Eduard vacuum pump |
1 |
pc |
|
8 |
Oil mist filter |
1 |
pc |
|
9 |
Water Analyser |
1 |
pc |
|
10 |
Oxygen analyser |
1 |
pc |
|
11 |
Instruction manual |
1 |
pc |
|
Technical parameters:
Boxes |
||
Description |
Material: Stainless steel 1.4301 (SUS type 304), thickness 3 mm Net dimensions: 1800mm(L) x 950mm(W) x 1700mm(H) |
|
Volume |
2.9 m³ |
|
Front window |
Panel: 8 mm thick safety toughened glass or 10 mm thick polycarbonate (optional) Dimensions: 1735mm(L) x 839mm(H) |
|
Glove opening |
Hard aluminium or paraformaldehyde (optional) Calibre 220 mm, O-ring seal |
|
Gloves |
Material: butyl rubber Thickness: 0.4 mm or 0.8 mm (optional) |
|
Filters |
Outlet and inlet filters, filtration <0.3μm |
|
Lighting |
LED lighting in the upper part of the front window roof |
|
Leakage rate |
Leak detection according to ISO 10648-2 : 1994 / EJ/T 1096-1999 "Hermetically sealed chambers - Part 2: Classification of hermeticity and related test methods" Oxygen content method and pressure change method for testing of chambers according to Class 1 hermeticity < 0.001 vol%/h Final acceptance test. |
|
GP20 gas purification system |
||
Description |
Automatic removal of H2O and O2 Single clean-up column system with automatic regeneration (optional GP200 double clean-up column) Sealed gas circulation lines |
|
Voltage used |
AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional) |
|
Working gases |
Working gases: N2, Ar, He (purity ≥ 99.999%) Regenerative gas: H2 accounts for 5-10%, the rest is working gas (purity ≥ 99.999%) |
|
Vacuum pumps |
Specifications: Rotary vane vacuum pump with oil mist filter, with gas ballast control Flow rate: 12 m³/h (7 cfm), double baseplate, vacuum < 2 x 10-3 mbar or dry pump (optional) |
|
Circulation units |
Oil-free high-speed fans Air volume: 80 m³/h |
|
Valves |
KF40 High vacuum valve |
|
Leakage rate |
Leak detection according to ISO 10648-2 : 1994 / EJ/T 1096-1999 "Hermetically sealed chambers - Part 2: Classification of hermeticity and related test methods" Oxygen content method and pressure change method for testing of chambers according to class 1 hermeticity < 0.001 vol%/h Final acceptance test. |
|
Control cabinet dimensions |
600mm (L) x 800mm (D) x 870mm (H) |
|
Transition cabin |
||
Large Transitional Cabin |
Materials |
Stainless steel type 304(1.4301), thickness 3 mm |
Size |
φ360mmx600mm(L) or φ390mmx600mm(L) (optional) |
|
Vacuum level |
< 1 x 10-2 mbar |
|
Small Transitional Cabin |
Materials |
Stainless steel type 304(1.4301),, thickness 2 mm |
Size |
φ150mm x 330mm(L) |
|
Vacuum level |
< 1 x 10-2 mbar |
|
Cleaning systems |
||
Description |
By setting the corresponding time and pressure, the system can automatically displace the gas to the chamber. |
|
Analyzers |
||
Oxygen analyser |
Size |
205 mm (L) x 80 mm (W) x 60 mm (H) |
Measurement range |
0-1000 ppm |
|
Other Oxygen Analysers |
GE oxy.IQ™ Oxygen Transmitter |
|
Moisture analyser |
Size |
205 mm (L) x 80 mm (W) x 60 mm (H) |
Measurement range |
0-500 ppm |
|
Other water analysers |
GE VeriDri™ Dew Point Transmitter |
|
Solvent purification systems |
||
Description |
Material: Stainless steel 1.4301 (SUS type 304), thickness 3 mm Internal dimensions: 220mm(Φ) x 450mm(H) High quality activated carbon |
|
Clean (Class 100) high efficiency purification circulation system |
||
Description |
The maximum concentration limit of suspended particles in the controlled environment in the chamber is greater than or equal to the required particle size (pcs/m³) by means of a high efficiency class 100 clean environment filtration and purification system ≥ (suspended particle diameter) 5.0μm less than 29pcs/m³ ≥ (suspended particle diameter) 0.5μm less than 3520 /m³ |