CR2032/2025/2016 Coin Cell Assembly Machine Plant For Lab Scale Lithium-ion Battery Research
Contact Person:Louis Yang Email: Louis@chinabatterymachine.com Tel:+86 13003860308 Whatsapp: +86 13003860308 Wechat:18659217588
Email: Louis@chinabatterymachine.com
Tel:+86 13003860308
Whatsapp: +86 13003860308
Wechat:18659217588
Item No.:
LITH-5V10mAPayment:
Credit Card, Paypal, T/T , Western Union, LCLead Time:
5 days5V10mA 8 Channels Battery Tester For Coin Cell Charge Discharge Testing
Technical parameters
Project index
Parameter index
Input Power
AC 220V ±10% / 50Hz
Resolution
AD: 16bit; DA: 16bit
Input Resistance
≥1G Ω
Input Power
25W
Voltage
Constant voltage range control
25mV~5V
Minimum discharge voltage
-5V
Accuracy
± 0.05% of FS
Stability
± 0.05% of FS
Current
Per Channel Current Range
Range1: 5uA~1mA; Range2: 1mA~5mA; Range3: 5mA~10mA
Accuracy
± 0.05% of FS
Constant voltage cut-off current
Range1: 2uA; Range2: 0.01mA; Range3: 0.02mA
Stability
± 0.05% of FS
Power
Per Channel Output Power
0.05W
Stability
± 0.1% of FS
Time
Current Response Time(10%FS~90%FS)
<500us
Step Time Range
1s≤Single Step Time Range≤365*24 h,
Time Form Support 00 : 00 : 00(h : min : s)
Data Recording
Record Condition
Min. Record Time: 100ms
Min. Record Voltage: 10mV
Min. Record Current:Range1: 2uA; Range2: 0.01mA; Range3: 0.02mA
Record Frequency
10Hz
Charge
Charge Mode
Constant Current Charge, Constant Voltage Charge,
CC-CV Charge , CP-Charge
End Condition
Voltage、Current、Relative Time、Capacity、-△V
Discharge
Discharge Mode
Constant Current Discharge CP-D CR-D
End Condition
Current、Current、Relative Time、Capacity
Pulse Model
Charge
Constant Current、Constant Power
Discharge
Constant Current、Constant Power
Min Pulse Width
500ms
Pulse Number
Single Pulse Step Support 32 different Pulse
Charge r To Discharge
One Pulse Step Can Support Continuous Charge And Discharge Change
Stop Condition
Voltage、 Relative Time
DCIR Testing
Support Custom Access Point And Count The DCR
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop Function, Max Support 3 Layers
Protection
l Power-down Data Protection
l Offline test function
l Setting Protection Condition,Setting Parameter: Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
IP protection level
Protection grade IP20
Channel characteristics
Constant current source and constant voltage source adopt double closed loop structure
Channel control mode
Independent control
Voltage and Current Testing Sample
4-wire connecting
Noise
<45dB
Data Management
MySQL Database
Communication Means
TCP/IP Protocol
Server operating system
Windows 7
Data Output
EXCEL、TXT
Server disk configuration
500GB
Communication Interface
Ethernet Port
Leakage current
0.005μA
Main Channels
8
Dimensions(W*D*H, mm)
1U(19")443*310*48 per unit
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃(Within the range of 25±10℃, the measurement accuracy is guaranteed: the accuracy drift is 0.005% of FS /℃) |
Storage Temperature Range |
-10℃~50℃ |
Working Environment Relative Humidity Range |
≤70% RH(No condensation) |
Storage Environment Relative Humidity Range |
≤80% RH(No condensation) |
Equipment Picture |
|
Picture for Reference Only, take the material object as the standard. |