5 daysLab Small High Precision Rotary Viscometer Suitable for Precious And Rare Sample Measurement
The digital rotary viscometer adopts coaxial cylinder structure, using small sample adapter, the sample quantity required for each measurement is very small, only 7ml-13ml (rotor 0 is 21ml), optional constant temperature water jacket with cycle, with constant temperature tank to control the sample under test. The operation is very convenient and the measurement is accurate. very suitable for precious, rare sample measurement.
characteristic:
1. Timing measurement function
2. Coaxial cylinder structure
3. Using a spindle rotor, the sample size required for testing is very small
4. Two RS232 interfaces with direct connection to micro printer and computer
model |
LV-SSR |
display mode |
digital display |
speed(r/min) |
0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100
Total 18 |
rotor |
18#,25#,31#,34# (standard configuration) |
measuring range |
3-1.6M (mPa﹒s) |
Sample size |
18# rotor:3 –10K; 7ml
25# rotor:480 –1.6M; 9ml
31# rotor:30 –100K; 10.5ml
34# rotor:60 –200K; 11ml |
measurement error |
±3% (Newtonian liquid) |
repetitive error |
±1.5% (Newtonian liquid) |
output interface |
Two RS232 interfaces to connect printer and computer |
Temperature Probe Interface |
standard configuration |
outline dimension |
300 × 300 × 450(mm) |
2. Detailed technical parameters of the RV-SSR / HA-SSR / HB-SSR rotary viscometer:
model |
RV-SSR |
HA-SSR |
HB-SSR |
display mode |
digital display |
||
speed(r/min) |
0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100
Total 18 |
||
rotor |
21#、27#、28#、29# (standard configuration) |
||
measuring range |
50 – 2M
21# rotor:50-100K
27# rotor:250-500K
28# rotor:500-1M
29# rotor:1K-2M |
100 – 4M
21# roto:100-200K
27# roto:500-1M
28# roto:1K-2M
29# roto:2K-4M |
400 – 16M
21# roto:400-800K
27# roto:2K-4M
28# roto:4K-8M
29# roto:8K-16M |
Sample size |
21# roto: 7.8ml
27# roto: 11.3ml
28# roto: 12.6ml
29# roto: 11.5ml |
||
measurement error |
±3% (Newtonian liquid) |
||
repetitive error |
±1.5% (Newtonian liquid) |
||
output interface |
Two RS232 interfaces to connect printer and computer |
||
Temperature Probe Interface |
standard configuration |
||
outline dimension |
300 × 300 × 450(mm) |