CR2032/2025/2016 Coin Cell Assembly Machine Plant For Lab Scale Lithium-ion Battery Research
Contact Person:Louis Yang Email: Louis@chinabatterymachine.com Tel:+86 13003860308 Whatsapp: +86 13003860308 Wechat:18659217588
Email: Louis@chinabatterymachine.com
Tel:+86 13003860308
Whatsapp: +86 13003860308
Wechat:18659217588
Item No.:
LITH-5V50mAPayment:
Credit Card, Paypal, T/T , Western Union, LCLead Time:
5 days5V50mA 8 Channels Tri-range Coin Cell Analyzer For Lithium Battery Capacity Testing
Technical parameters
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
Resolution |
AD: 16bit; DA: 16bit |
|
Input Resistance |
≥1G Ω |
|
Input Power |
25W |
|
Voltage |
Constant voltage range control |
25mV~5V |
Minimum discharge voltage |
-5V |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
Range1: 5uA~1mA; Range2: 1mA~25mA; Range3: 25mA~50mA |
Accuracy |
± 0.05% of FS |
|
Constant voltage cut-off current |
Range1: 2uA; Range2: 50uA; Range3: 100uA |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
0.25W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time(10%FS~90%FS) |
<500us |
Step Time Range |
1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00:00(h、min、s、ms) |
|
Data Recording |
Record Condition |
Min. Record Time: 100ms |
Min. Record Voltage: 10mV |
||
Min. Record Current:Range1: 2uA; Range2: 50uA; Range3: 100uA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, CC-CV Charge , CP-Charge |
End Condition |
Voltage、Current、Relative Time、Capacity、-△V |
|
Discharge |
Discharge Mode |
Constant Current Discharge CP-D CR-D |
End Condition |
Current、Current、Relative Time、Capacity |
|
Pulse Model |
Charge |
Constant Current、Constant Power |
Discharge |
Constant Current、Constant Power |
|
Min Pulse Width |
500ms |
|
Pulse Number |
Single Pulse Step Support 32 different Pulse |
|
Charge r To Discharge |
One Pulse Step Can Support Continuous Charge And Discharge Change |
|
Stop Condition |
Voltage、 Relative Time |
|
DCIR Testing |
Support Custom Access Point And Count The DCR |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function, Max Support 3 Layers |
|
Protection |
l Power-down Data Protection |
|
l Offline test function |
||
l Setting Protection Condition,Setting Parameter: Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time |
||
IP protection level |
Protection grade IP20 |
|
Channel characteristics |
Constant current source and constant voltage source adopt double closed loop structure |
|
Channel control mode |
Independent control |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<45dB |
|
Data Management |
MySQL Database |
|
Communication Means |
TCP/IP Protocol |
|
Server operating system |
Windows 7 |
|
Data Output |
EXCEL、TXT |
|
Server disk configuration |
500GB |
|
Communication Interface |
Ethernet Port |
|
Leakage current |
0.005μA |
|
Main Channels |
8 |
|
Dimensions(W*D*H, mm) |
1U(19")483*310*48 per unit |
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃(Within the range of 25±10℃, the measurement accuracy is guaranteed: the accuracy drift is 0.005% of FS /℃) |
Storage Temperature Range |
-10℃~50℃ |
Working Environment Relative Humidity Range |
≤70% RH(No condensation) |
Storage Environment Relative Humidity Range |
≤80% RH(No condensation) |