5V2A 3A 5A 6A 256 Channel Battery Tester is selectable according to your request.
Features:
1. Each device can carry out constant current and constant voltage charging and constant current discharge test on 256 batteries meeting the voltage range.
2. Adopt the constant current constant voltage power supply of the invention patent, constant current to constant voltage switching without impact, especially suitable for the charging requirements of lithium-ion battery.
3. The AVR single-chip computer is used as the control center of the equipment, and the peripheral sampling circuit is used. The equipment can be controlled by the superior computer. When the computer is connected, the complete charge discharge curve of all channels can be saved, or it can be separated from the superior computer. Through the operation of the control panel, the constant current and voltage charging, constant current discharge test, time sorting and other work can be completed.
4. Each battery has an independent constant current and voltage source, and the self-made circuit does not affect each other.
5. Detect the voltage of each battery in real time. When charging, charge at constant current first. When the battery voltage reaches the set value, it will smoothly switch to constant voltage charging. When the set time or current termination conditions are met, the charging will end. During constant current discharge, when the battery voltage is lower than the set value, the discharge is ended and the corresponding battery indicator light is on.
6. It has the function of power-off protection, and can continue to operate after receiving the original workflow
7. The power tube is 50N06, which is suitable for batteries requiring low discharge voltage, such as lithium iron phosphate battery
8. The upper computer can set 32 working step parameters and 256 cycles, and each upper computer can be connected with 1-10 sets of single-chip system (less than 10 sets are recommended).
Specifications
Number of Device Channels
The whole machine has 256 channels in total
Workflow Control Mode
Whole cabinet control
Charging Mode
Constant current and constant voltage
Charging Cut-off Conditions
Voltage, current, time, capacity
Discharge Mode
Constant current
Discharge Cut-off Conditions
Voltage, time and capacity
Sampling Inspection Cycle
≤10s
Voltage Measurement Range
0 ~ 5V,
Resolution 1mV
Battery Voltage Range
Charging: 0 ~ 4.5V,
Discharging: 4.5 ~ 2V
Constant Voltage Range
3~4.5V
Voltage Accuracy
±(0.05%RD+0.1%FS)
Current Range
Charge 0.025-6A,
Discharge 0.025-6A,
Resolution 1mA
Current Accuracy
±(0.1%RD+0.1%FS)
Time Frame
Any setting within 0 ~ 30000 minutes, time unit is min
Time Accuracy
≤±0.1%
Fixture Type
Cylindrical four wire fixture
Fixture Spacing
35mm
Support Battery Height
0~90mm
Working Power Supply
Three phase four wire system, AC380V ± 5%, 50Hz, power consumption ≤ 14KW
Communication Mode
RS485,baud rate57600
Overall Dimension
720mm(Width)*500mm(Deep)*1840mm(High)
Work Environment
Temperature: 0-40 ℃, relative temperature ≤ 85%
Full Load Operating Current
he maximum phase line is 30A, and the maximum zero line is 3A