CE-6000 Specification
|
1、Model
|
1. Material code
|
CE-6002n-100V60A-H
|
2、Channels information
|
1. Channels quantity
|
Channels quantity in one unit
|
2
|
2. Main channel
|
Channel feature
|
Constant current source and constant voltage source dual closed loop control
|
|
Channel control mode
|
Independent control
|
|
Channel parallel connection
|
Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode.
|
3、Power grid side parameters
|
1.Input power
|
|
AC380V±15% 50/60±5Hz
|
2.Power factor
|
|
≥99%(Full load)
|
3.THDi
|
|
≤5%(Full load)
|
4.Input resistance
|
|
≥1MΩ
|
5.Input power
|
|
14.1KW
|
6.Input current
|
|
21.5A/single
|
7.Overall system efficiency(Max)
|
|
90%
|
8.Noise
|
|
≤65dB
|
9.Voltage and current sampling
|
|
Four-wire connection(same port for charging and discharging)
|
10.Power control module type
|
|
MOSFET
|
11.Input power wiring method
|
|
Three-phase-five wire system
|
12.Power input protection
|
|
Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc.
|
4、Functions and performances
|
1. Voltage
|
Output range
|
Charge:0V~100V
|
|
|
Discharge:3V~100V
|
|
Min discharge voltage
|
3V
|
|
Accuracy
|
±0.02% of FS
|
|
Resolution
|
24bit
|
2. Current
|
Output range
|
0.3A~60A
|
|
Accuracy(independent range)
|
±0.05% of FS
|
|
CV cut-off current
|
60mA
|
|
Resolution
|
24bit
|
3. Power
|
Single channel output power
|
6KW
|
|
Whole machine output power
|
12KW
|
4. Time
|
Current response time
|
≤3ms
|
|
Current conversion time
|
≤6ms
|
|
Min. step time
|
0.1s
|
5. Charge/Discharge modes
|
Charge/Discharge modes
|
CCC, CVC, CC-CVC, CPC
|
|
|
CCD, CVD, CPD, CRD
|
|
Cut-off condition
|
Voltage, Current, ΔTime, Capacity, -ΔV
|
6. Simulation
|
Charge
|
Current, Power
|
|
Discharge
|
Current, Power
|
|
Switch
|
Support continuous switching between charge and discharge
|
|
Cut-off condition
|
Time, step line
|
|
Steps file lines
|
1,000,000
|
7. Pulse Mode
|
Charge
|
Current ,power
|
|
Discharge
|
Current, Power
|
|
Min pulse
|
100ms
|
|
Pulse counts
|
Up to 32
|
|
Charge and discharge switch
|
supported
|
|
Cut-off condition
|
Voltage, ΔTime
|
8. DCIR
|
|
DCIR by calculation
|
9. Safely protection
|
Software protection
|
Power off data protection
|
|
|
Offline mode function
|
|
|
Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc.
|
|
Hardware protection
|
Anti-reverse connection, over-voltage, over-current, over-temperature, etc.
|
5、Data management and analysis
|
1. Step setting method
|
|
Form editing
|
2. Data report
|
Recording conditions
|
Minimum time interval: 10ms(connected with AUX channel:100ms)
|
|
|
Minimum voltage interval: 0.2V
|
|
|
Minimum current interval: 0.12A
|
|
Recording frequency
|
100Hz(connected with AUX channel:10Hz)
|
3. Database
|
|
MySQL database
|
4. Data output
|
|
Excel, Txt
|
5. Curve type
|
|
Templates available, customization supported
|
6. Bar code scanning
|
|
Support bar-code scanning function
|
|
|
Management and traceability of historical data
|
6、Communication
|
1. Host computer communication
|
|
TCP/IP protocol
|
2. Communication port
|
|
Ethernet
|
3. Communication baud rate of the testers
|
|
1M
|
4. Host computer communication baud rate
|
|
10M~100M adaptive
|
5. Communication setup
|
|
Set up a LAN(local area network) through switches and routers
|
6. Communication expansion(optional)
|
|
Support CAN, RS485 communication and BMS communication, with DBC configuration function
|
7、Environmental requirements, dimension and weight
|
1. Operation environment temperature
|
|
-10℃~40℃(When the temperature is 25±10℃, the accuracy error caused by temperature change is less than 0.005% of FS per degree)
|
2. Storage environment temperature
|
|
-20℃~50℃
|
3. Operation environment humidity
|
|
≤70% RH(no moisture condensation)
|
4. Storage environment humidity
|
|
≤80% RH(no moisture condensation)
|
5. Dimension W*D*H
|
|
600*800*900(mm)
|
6. Weight
|
|
about 111.1KG
|