5V 100A 8 Channel Battery Charge And Discharge Testing Machine Capacity Tester
Introduction
Test object: power battery, energy storage battery, super capacitor;
Test items: current, voltage, charge and discharge time, capacity, power, pulse charge and discharge, DC internal resistance
Battery performance test: power, energy, capacity, overshoot, over discharge;
Sorting: battery consistency; Cycle life test; Rate charge discharge test; DC internal resistance;
Pulse test pulse, mixed power pulse characteristic (HPPC).
Auxiliary channels can be added to test the temperature during battery charging and discharging
Specifications
Project Index
|
Parameter Index
|
Input AC Power
|
AC 380V ±10% / 50Hz
|
Input Impedance
|
≥100KΩ
|
Input Power
|
7089W
|
Resolution
|
AD:16bit;DA:16bit
|
Channel Features
|
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
|
Channel Control Mode
|
Independent Control
|
Voltage
|
Each Channel Voltage Range
|
0.025mV~5V
|
Ll
|
Lowest Discharge Voltage
|
2V
|
|
Accuracy
|
± 0.1% of FS
|
|
Stability
|
± 0.1% of FS
|
Current
|
Each Channel Current Range
|
Range :0.5A~100A
|
|
Cut Off Current
|
0.2A
|
|
Accuracy
|
± 0.1% of FS
|
|
Stability
|
± 0.1% of FS
|
Power
|
Each Channel Max. Output Power
|
500W
|
|
Stability
|
0.2% of FS
|
Time
|
Current Rise Time
|
The current gets to (10%-90%) hardware rise time is 20ms
|
|
Step Time Range
|
1s≤Single Step Time Range≤365*24 h,
SupportTime Form: 00:00:00:00(h、min、s、ms)
|
Data Recording
|
Record Condition
|
Min. Record Time:100ms
|
|
|
Min. Record Voltage:10mV
|
|
|
Min. Record Current:200mA
|
|
Record Frequency
|
10Hz
|
Charge
|
Charge Mode
|
Constant Current Charge、Constant Voltage Charge、Constant Power Charge、Constant Current and Constant Voltage Charge
|
|
End Conditon
|
Voltage、Current、Relative Time、Capacity、Relative Voltage
|
Discharge
|
Discharge Mode
|
Constant Current Discharge、Constant Power Discharge、Constant Resistance Discharge
|
|
End Condition
|
Current、Voltage、Relative Time、Capacity、Relative Voltage
|
Cycle
|
Loop Measure Range
|
1~65535 times
|
|
Max Steps Per Loop
|
254
|
|
Nested Loop
|
Nested loop Function,Max Support 3 Layers
|
Pulse Model
|
Charge
|
Constant Current、Constant Power
|
|
Discharge
|
Constant Current、Constant Power
|
|
Min Pulse Width
|
500ms
|
|
Pulse Number
|
Single Pulse Step Support 32 different Pulse
|
|
Charge r To Discharge
|
One Pulse Step Can Support Continuous Charge And Discharge Change
|
Stop Condition
|
Voltage、 Relative Time
|
DCIR Testing
|
Support Custom Access Point And Count The DCR
|
Channel Parallel
|
Support Channel Parallel(4 channels max),Under Parallel Without Pulse Function
|
Protective Function
|
Software Protection
|
l Power-down Data Protection
|
l Off-line Testing Function
|
l Setting Protection Condition,Setting Parameter:Low Voltage Limit、Upper Voltage Limit、Low Current Limit、Upper Current Limit、Delay Time
|
Hardware Protection
|
Additional Anti-reverse Protection Model
|
Data Output
|
EXCEL、TXT
|
Communication Interface
|
Ethernet Port
|
No. Of Channels Per Unit
|
8
|
Dimensions (W*D*H)
|
600*600*1000(mm)
|
Equipment Working Environment
Project Index
|
Parameter Index
|
Working Temperature
|
0℃~40℃
|
Storage Temperature
|
-10℃~50℃
|
Working Humidity
|
≤ 70% RH
|
Storage Humidity
|
≤80% RH
|