Item No.:
LITH-5V1APayment:
Credit Card, Paypal, T/T , Western Union, LCLead Time:
5 days5V1A 8 Channels Pouch Cell Tester For Lithium Battery Capacity Testing With Optional Clamps
Technical parameters
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
Resolution |
AD: 16bit; DA: 16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
80W |
|
Voltage |
Constant voltage range control |
25mV~5V |
|
Minimum discharge voltage |
0.5V (within 2m channel line) |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
Current |
Per Channel Current Range |
Range1: 0.5mA~0.1A; Range2: 0.1A~0.5A; Range3: 0.5A~1A |
|
Accuracy |
± 0.05% of FS |
|
Constant voltage cut-off current |
Range1: 0.2mA; Range2: 1mA; Range3: 2mA |
|
Stability |
± 0.05% of FS |
Power |
Per Channel Output Power |
5W |
|
Stability |
± 0.1% of FS |
Time |
Current Response Time(10%FS~90%FS) |
<2ms |
|
Step Time Range |
1s≤Single Step Time Range≤365*24 h, Time Form Support 00 : 00 : 00(h : min : s) |
Data Recording |
Record Condition |
Min. Record Time: 100ms |
|
|
Min. Record Voltage: 10mV |
|
|
Min. Record Current:Range1: 0.2mA; Range2: 1mA; Range3: 2mA |
|
Record Frequency |
10Hz |
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, CC-CV Charge , CP-Charge |
|
End Condition |
Voltage、Current、Relative Time、Capacity、-△V |
Discharge |
Discharge Mode |
Constant Current Discharge CP-D CR-D |
|
End Condition |
Current、Current、Relative Time、Capacity |
Pulse Model |
Charge |
Constant Current、Constant Power |
|
Discharge |
Constant Current、Constant Power |
|
Min Pulse Width |
500ms |
|
Pulse Number |
Single Pulse Step Support 32 different Pulse |
|
Charge r To Discharge |
One Pulse Step Can Support Continuous Charge And Discharge Change |
|
Stop Condition |
Voltage、 Relative Time |
DCIR Testing |
Support Custom Access Point And Count The DCR |
|
Cycle |
Loop Measure Range |
1~65535 times |
|
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function, Max Support 3 Layers |
Protection |
l Power-down Data Protection |
|
|
l Offline test function |
|
|
l Setting Protection Condition,Setting Parameter: Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time |
|
IP protection level |
Protection grade IP20 |
|
Channel characteristics |
Constant current source and constant voltage source adopt double closed loop structure |
|
Channel control mode |
Independent control |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<55dB |
|
Data Management |
MySQL Database |
|
Communication Means |
TCP/IP Protocol |
|
Server operating system |
Windows 7 |
|
Data Output |
EXCEL、TXT |
|
Communication Interface |
Ethernet Port |
|
Main Channels |
8 |
|
Dimensions(W*D*H, mm) |
2U(19")443*330*84.5 per unit |
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃ |
Storage Temperature Range |
-10℃~45℃ |
Working Environment Relative Humidity Range |
≤70% RH |
Storage Environment Relative Humidity Range |
≤80% RH |
Equipment Picture |
|
Picture for Reference Only, take the material object as the standard. |