Technical parameters
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD: 16bit; DA: 16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Voltage Range |
Charge: 0.025V~5V; Discharge: 1.0V~5V |
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
Range1: 0.5mA~1A; Range2: 0.1A~3A; Range3: 3A~6A |
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time(10%FS~90%FS) |
1ms |
Step Time Range |
1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h、min、s) |
|
Data Recording |
Record Condition |
Min. Record Time: 100ms |
Min. Record Voltage: 10mV |
||
Min. Record Current:Range1: 0.2mA;Range2: 6mA; Range3: 12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, CC-CV Charge , CP-Charge |
End Condition |
Voltage、Current、Relative Time、Capacity、-△V |
|
Discharge |
Discharge Mode |
Constant Current Discharge CP-D CR-D |
End Condition |
Current、Current、Relative Time、Capacity |
|
Pulse Model |
Charge |
Constant Current、Constant Power |
Discharge |
Constant Current、Constant Power |
|
Min Pulse Width |
500ms |
|
Pulse Number |
Single Pulse Step Support 32 different Pulse |
|
Charge r To Discharge |
One Pulse Step Can Support Continuous Charge And Discharge Change |
|
Stop Condition |
Voltage、 Relative Time |
|
DCIR Testing |
Support Custom Access Point And Count The DCR |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function, Max Support 3 Layers |
|
Protection |
Software Protection |
l Power-down Data Protection |
l Setting Protection Condition,Setting Parameter: Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time |
||
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |
|
Data Management |
MySQL Database |
|
Communication Means |
TCP/IP Protocol |
|
Data Output |
EXCEL、TXT |
|
Communication Interface |
Ethernet Port |
|
Main Channels |
8 |
|
Dimensions |
3U, W*D*H:480*730*130(mm)per unit |
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃ |
Storage Temperature Range |
-10℃~45℃ |
Working Environment Relative Humidity Range |
30%-80% RH |
Storage Environment Relative Humidity Range |
30%-90% RH |
Equipment Picture |
|